NDIR is a technique that has a long track record in this community. In NDIR, an infrared lamp shines the light through a tube filled with sample of air. Gas molecules in the experimental tube absorb the light of the wavelength matching with the size of gas molecules according to Beer-Lambert Law. The detector measures the attenuation of the wavelengths in order to determine the gas concentration. The detector is equipped with the optical filter that removes all light wavelengths, except the wavelengths that are absorbed by the gas of interest (Hummelga et al. 2015).
 
NDIR is a technique that has a long track record in this community. In NDIR, an infrared lamp shines the light through a tube filled with sample of air. Gas molecules in the experimental tube absorb the light of the wavelength matching with the size of gas molecules according to Beer-Lambert Law. The detector measures the attenuation of the wavelengths in order to determine the gas concentration. The detector is equipped with the optical filter that removes all light wavelengths, except the wavelengths that are absorbed by the gas of interest (Hummelga et al. 2015).
  
<div class="tablecaption" id="table8">TABLE 8 STRENGTHS AND LIMITATIONS OF NDIR</div>
+
TABLE8STRENGTHANDLIMITATIONSOFNDIR
{| class="wikitable"
 
|-
 
! scope="col" | Strengths
 
! scope="col" | Limitations
 
|-
 
! scope="row" | Low cost of purchase and running
 
| Detection range and sensitivity for different gases varies within very large range
 
|-
 
! scope="row" | Stable long term operation and small calibration efforts, stable even after long term storage
 
| Measurements depend strongly on the ambient conditions, such as temperature and atmospheric pressure due to variability in gas density
 
|-
 
! scope="row" |
 
| Water vapours interfere with the measurements
 
|}
 
Producers of NDIR sensors are presented in table 13
 
  
<div class="tablecaption" id="table9">TABLE 9 COMPANIES PRODUCING NDIR</div>
+
TABLE9COMPANIESPRODUCINGNDIR
{| class="wikitable"
 
! scope="col" | Company
 
! scope="col" | website
 
|-
 
! scope="row" | Alphasense
 
| http://www.alphasense.com/
 
|-
 
! scope="row" | Dynament
 
| http://www.dynament.com/
 
|-
 
! scope="row" | Edinburgh Sensors
 
| https://edinburghsensors.com/
 
|-
 
! scope="row" | Sensors
 
| https://sensors-inc.com/
 
|-
 
! scope="row" | Heimann Sensor GmbH
 
| http://www.heimannsensor.com/
 
|-
 
! scope="row" | Li-Cor Environmental
 
| https://www.licor.com/
 
|-
 
! scope="row" | Senseair
 
| https://senseair.com/
 
|}
 
  
 
====2.1.2.6 Cavity ring down spectroscopy (CRDS)====
 
====2.1.2.6 Cavity ring down spectroscopy (CRDS)====

Please note that all contributions to may be edited, altered, or removed by other contributors. If you do not want your writing to be edited mercilessly, then do not submit it here.
You are also promising us that you wrote this yourself, or copied it from a public domain or similar free resource (see Copyrights for details). Do not submit copyrighted work without permission!

Cancel Editing help (opens in new window)

Templates used on this page: